Clinical Projects - Medical Physics Consulting
"Your projects are done right without wasted time"
  • We will promptly complete and deliver our reports and dosimetry data books.
     
  • We will engage your staff in practical and effective QA processes.
     
  • You maximize machine up-time, treatment efficiency and gain processes for problem solving. 

Shielding Design and Verification

Our design team works with your architects and uses the latest protocols to provide optimum shielding designs for safety and efficiency in your clinic.
Shielding design/analysis (from blueprints)
X-ray and Neutron Survey (we supply equipment)

Acceptance Testing

Our FASTRAK method enables us to accept your machine in half the traditional time.
We perform all necessary tests to verify that the machine meets manufacturer’s specifications and establish a QA baseline. 

Absolute Calibration

Our calibrations are based on AAPM Task Groups TG 40, 51
We use our state-of-the-art equipment for all measurements.

Data Collection for Commissioning

With our FASTRAK method your machine will be commissioned in 1/3 of the traditional time.
All beam types, energies, accessories, and modalities
Measuring equipment required for data collection is supplied by P&CP.

Data Transfer

Includes all necessary processing of measured data into planning system format.

Beam Modeling, Review & Verification

 

 

  

Visit us at Booth #1426
ASTRO 2010
San Diego CA
 
 
 
An independent, confidential radiation therapy physics auditing program
 Why should your clinic have an independent medical physics audit?
  • Recently published findings of radiation treatment errors reveal that an audit of your QA program by an outside independent medical physics group can ensure patient safety.
P&CP offers you a safe and efficient auditing system to ensure a sustainable safeguard of your QA program.
  • Our specialists establish a custom program to close the gap between complex new technology and the time and experience of your staff
  • In light of recent concerns over radiation treatment errors, P&CP has become the auditor of choice in centers across the country. This was based on our decade long experience in program start-up, development and implementation of new technology.
     
 
“P&CP has performed exceptionally well in commissioning our new equipment and technology efficiently through experienced physicists with varied backgrounds and resources.”
Karen Johnson
Radiation Oncology Manager
Presbyterian Cancer Services/Charlotte, NC
Email us at: info@pandcp.com  or call us at: 704.897.1228